SIZE: 400*400/3mm thickness, the main tube is φ50mm*3mm, the vice tube is φ30mm*2mm, Brace is φ25mm*2mm, the normal length for one pc is 1m-4m, it can be stretched to 15m with max load 130kg.
Span In Meter(m) | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | |||||||||||||||||||||||||||||||||||||
Point Load In(kg) | 870 | 483 | 441 | 436 | 423 | 360 | 308 | 246 | 189 | 105 | 65 | |||||||||||||||||||||||||||||||||||||
Distrib Load In (kg/m) | 348 | 161 | 126 | 109 | 94 | 72 | 56 | 41 | 29 | 15 | 9 |
SIZE: 300*300/3mm thickness, the main tube is φ50mm*3mm, the vice tube is φ20mm*2mm, Brace is φ20mm*2mm, the normal length for one pc is 1m-4m, it can be stretched to 13m with max load 110kg.
Span In Meter(m) | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | |||||||||||||||||||||||||||||||||||||
Point Load In(kg) | 587 | 522 | 375 | 345 | 319 | 316 | 275 | 265 | 215 | 150 | 55 | |||||||||||||||||||||||||||||||||||||
Distrib Load In (kg/m) | 391 | 261 | 150 | 115 | 91 | 79 | 61 | 53 | 39 | 25 | 9 |
SIZE: 290*290/3mm thickness, the main tube is φ50mm*3mm, the vice tube is φ20mm*2mm, Brace is φ20mm*2mm, the normal length for one pc is 1m-4m,it can be stretched to 13m with max load 100kg.
Span In Meter(m) | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | |||||||||||||||||||||||||||||||||||||||
Point Load In(kg) | 557 | 500 | 348 | 327 | 298 | 268 | 248 | 240 | 193 | 126 | 50 | |||||||||||||||||||||||||||||||||||||||
Distrib Load In (kg/m) | 371 | 250 | 139 | 109 | 85 | 67 | 55 | 48 | 35 | 21 | 8 |